VEGAFLEX:
Level measurement with guided microwaves
In this type of radar level measurement, microwave pulses are conducted along a cable or rod probe and reflected by the product surface. The measuring probe ensures that the signal reaches the medium undisturbed. Liquids, solids and separation layers (interfaces) in liquids are commonly measured with this measuring technique.
The advantages
The sensors measure reliably even with:
- Steam generation
- Pressure and temperature fluctuations
- Dust and noise
- Condensation
Select a suitable sensor using the technical data.
» VEGAFLEX 61
Version
exchangeable cable (ø 2 mm, ø 4 mm) exchangeable rod (ø 6 mm)
Measuring range
cable: up to 32 m rod: up to 4 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature
-40 … +150 °C
Process pressure
-1 … +40 bar (-100 … +4000 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 62
Version
exchangeable cable (ø 6 mm) exchangeable rod (ø 16 mm)
Measuring range
cable: up to 60 m rod: up to 6 m
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature
-40 … +150 °C
Process pressure
-1 … +40 bar (-100 … +4000 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 63
Version
cable (ø 4 mm) rod (ø 10 mm)
Measuring range
cable: up to 32 m rod: up to 4 m
Process fitting
flanges from DN 50, 2“ Clamp from 1"
Process temperature
-40 … +150 °C
Process pressure
-0.5 … +16 bar (-50… +1600 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 65
Measuring range
up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature
-40 … +150 °C
Process pressure
-1 … +40 bar (-100 … +4000 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 66
Version
exchangeable cable (from ø 4 mm) exchangeable rod (from ø 6 mm) coax probe
Measuring range
cable up to 60 m rod up to 6 m coax up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 40, 2"
Process temperature
-200 … +400 °C
Process pressure
-1 … +400 bar (-100 … +40000 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 67
Version
exchangeable cable (ø 4 mm) exchangeable rod (ø 6 mm) coax probe
Measuring range
cable up to 60 m rod up to 6 m coax up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature
-200 … +400 °C
Process pressure
-1 … +400 bar (-100 … +40000 kPa)
| | |
» VEGAFLEX 61
Version
exchangeable cable (ø 2 mm, ø 4 mm) exchangeable rod (ø 6 mm)
Measuring range
cable: up to 32 m rod: up to 4 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature
-40 … +150 °C
Process pressure
-1 … +40 bar (-100 … +4000 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 62
Version
exchangeable cable (ø 6 mm) exchangeable rod (ø 16 mm)
Measuring range
cable: up to 60 m rod: up to 6 m
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature
-40 … +150 °C
Process pressure
-1 … +40 bar (-100 … +4000 kPa)
SIL qualification
up to SIL2
| | » VEGAFLEX 66
Version
exchangeable cable (from ø 4 mm) exchangeable rod (from ø 6 mm) coax probe
Measuring range
cable up to 60 m rod up to 6 m coax up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 40, 2"
Process temperature
-200 … +400 °C
Process pressure
-1 … +400 bar (-100 … +40000 kPa)
SIL qualification